Leave Your Message

Hydz φ34H9 External Drive Wired Piezo Sounder - China Factory Suppliers for Alarm Functions

Key Features:

1. Premium D34*H9mm external drive piezoelectric wire leaded type, sourced directly from reliable suppliers in China.

2. Features a secure screw fixation and operates on a 1/2 square wave drive for enhanced performance.

3. An excellent choice for alarm function designs, ideal for a variety of applications.

4. Customized terminal connectors are available, showcasing our factory's dedication to meeting specific client needs.

    Electrical Characteristics

    Part No: HYR-3409
    No. Specification Parameter Value / Condition
    1 Resonance Frequency (KHz) 3.6 ± 0.3
    2 Max Input Voltage (Vp-p) 30
    3 Capacitance at 120Hz (nF) 28000 ± 30% at 120Hz / 1V
    4 Sound Output at 10cm (dB) Min. 85 at 10cm, 12Vp-p, 3.6KHz
    5 Current Consumption (mA) ≤ 3 at 3.6KHz Square Wave 12Vp-p
    6 Operating Temperature (°C) -20 ~ +70
    7 Storage Temperature (°C) -30 ~ +80
    8 Weight (g) 0.7
    9 Housing Material Black ABS

    Dimensions and Material (unit: mm)

    Dimensions and Material drawing HYR-3409

    Tolerance: ±0.5mm Except Specified

    Notice (Handling)

    • 1
      The component may be damaged if mechanical stress exceeding specifications is applied.
    • 2
      Take care to protect the operating circuit from surge voltage resulting from excessive force, falling, shock or temperature change.
    • 3
      Avoid excessive pulling of the lead wire because the wire may break or the soldering point come off.

    Notice (Storage and Operating Condition)

    1. Product Storage Condition

    Please store the products in a room where the temperature/humidity is stable and avoid places where there are large temperature changes.

    Please store the products under the following conditions:

    Temperature: -10 to +40°C Humidity: 15 to 85% R.H.

    2. Expiration Date on Storage

    Expiration date (shelf life) of the products is six months after delivery under the conditions of a sealed and unopened package. Please use the products within six months after delivery.

    If you store the products for a long time (more than six months), use carefully because the products may be degraded in solderability due to storage under poor conditions.

    Please confirm solderability and characteristics for the products regularly.

    3. Notice on Product Storage

    Please do not store the products in a chemical atmosphere (Acids, Alkali, Bases, Organic gas, Sulfides and so on), because the characteristics may be reduced in quality, may be degraded in solderability due to storage in a chemical atmosphere.

    Frequently Asked Questions (FAQ)

    Q What is the resonance frequency and sound output of HYR-3409?

    The component operates at a resonance frequency of 3.6±0.3 KHz and delivers a sound output of at least Min. 85 dB measured at 10cm under 12Vp-p.

    Q What are the operational temperature limits for this part?

    The rated operating temperature range for HYR-3409 is from -20°C to +70°C, with a storage temperature tolerance from -30°C to +80°C.

    Q What are the recommended environmental conditions for storing HYR-3409?

    Products should be stored in an area with stable temperature and humidity, specifically between -10°C to +40°C and relative humidity of 15% to 85% R.H., away from rapid thermal fluctuations.

    Q What is the shelf life (expiration period) of the component?

    The shelf life is six months from delivery when kept in sealed and unopened original packaging. For storage exceeding six months, regularly verify solderability and functional characteristics before use.

    Q What precautions must be taken regarding chemical exposure during storage?

    Do not store the components in atmospheres containing chemicals such as acids, alkali, bases, organic gases, or sulfides, as these chemicals degrade product characteristics and solderability.

    Q What handling measures protect the product from mechanical and electrical damage?

    Avoid applying mechanical stress beyond specifications, protect against voltage surges from sudden shocks or drops, and refrain from pulling the lead wires to prevent wire detachment or breakage.